Share this page
back

Waterproofing and tiling in commercial kitchens and cool rooms

In commercial kitchens and cool rooms with surfaces to be clad in stone or ceramic, there are considerations, dependent on the area, related to exposure to aggressive media such as lactic acid, fatty acids, blood, cleaning materials, etc., for example. The choice of the waterproofing and installation system is geared towards chemical exposure. The corresponding ranges of the applicable load group must be specified by the planner in accordance with the ZDB data sheet or DIN 18534.
The optional use of a conductive strip and conductive lacquer between primer and the waterproofing membrane gives the possibility of a non-destructive test for impermeability of the membrane using a spark coil test to DIN 55670 under high voltage. The time consuming and costly testing of the waterproofing measures via a trial fill of the waterproofed area with water can be dispensed with.

Print page
LEVELLING

Cement-based patching mortar, 5 – 40 mm, wall/floor

Water repellent, rapid hardening screed mortar with high strength

PRIMING

Epoxy resin-based barrier primer

WATERPROOFING

Trowellable, chemically resistant bonded polyurethane based waterproof membrane

Special waterproof tape for heavy duty exposure and highly demanding areas

TILE INSTALLATION

Epoxy resin-based, chemical resistant thin-bed mortar

GROUTING

Chemical resistant fine grain epoxy resin-based grout, 3 component and solvent free

Silicone sealant for movement joints