Technical data sheet ASOL-FE Bitumen primer/protective coating, elastic, solvent-free
Material number
Contents
Unit of quantity
Packaging
Colour
202840009
1000
L
Container (IBC)
Black
202840006
5
Pail
202840007
14
202840008
28
Fields of application / waterproofing As protective coating to protect against pressure and non pressure seepage water As a primer For underground and shaft construction For interior and exterior use
Product features Latex-enhanced bituminous emulsion Ready to use
Advantages Can be applied by brush, roller and spray Solvent free Versatile
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 1/4
31/03/2025
Technical data sheet ASOL-FE Technical Data Material properties Product components Base material Consistency Density, ready to use product (ISO 1183-1) Radon diffusion constant [D]
Ready to use Bitumen/latex emulsion liquid, paste approx. 1.01 kg/dm³ 6.9*10-12 m²/s
Application Substrate/application temperature Consumption pro m² and mm layer thickness Consumption
approx. 5 - 30 °C approx. 1.5 l Protective coating: approx. 300–500 ml/m² per coat Membrane primer: approx. 100–125 ml/m² Bituminous primer: approx. 40 – 60 ml/m²
Processing equipment Aids/tools Brush Colour roller Primer brush Spray equipment
Suitable substrate Cement plaster Masonry work Concrete Old, firmly adhering bituminous substrates
Preparing the substrate Requirement for substrate 1. Dry 2. Load-bearing 3. Even 4. Pore open 5. Sealed in the surface 6. Free of adhesion inhibiting substances
Preparing the details 1. Depressions > 5 mm and mortar pockets, plaster grooves in brickwork, open butt or bed joints, damaged areas, large pored substrates or uneven masonry work must be levelled in advance with ASOCRET-M30. 2. Level recesses < 5 mm with ASOCRET-M30 or AQUAFIN-1K.
Preparing the surface 1. Cement paste and components that can be washed off must be removed mechanically. 2. Pre-screen with ASOCRET-M30 in the base slab-wall transition, at corners and edges and install a cove while still wet.
Application Protective coating 1. Apply ASOL-FE (diluted 1:5 with water) as a primer. 2. Apply the protective coating undiluted in at least two application steps. 3. At least three application steps are necessary when exposed to pressurised water. 4. The subsequent coat is always carried out after the previous coat has dried sufficiently.
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 2/4
Technical data sheet ASOL-FE Primer for COMBIDIC bituminous thick layer coating 1. Dilute ASOL-FE with water. (1:5) 2. Apply the diluted material with the chosen tool. 3. Apply the COMBIDIC bituminous thick layer coating only after the primer has completely dried.
Primer under KSK-Abdichtungsbahn or polymer bitumen welding membranes 1. Dilute ASOL-FE with water depending on the absorbency of the substrate. (max. 1:1) 2. Apply the diluted material with the chosen tool. 3. Do not apply the KSK-Abdichtungsbahn or polymer bitumen welding membrane until the primer has dried completely.
Cleaning tools Rinse tools with water immediately after use.
Drainage and protection boards for building components in contact with the ground The waterproofing must be protected against weathering influences and mechanical damage using suitable protective measures in accordance with DIN 18533. 1. The waterproofing must be totally dry. 2. Suitable protection and drainage boards can be fixed in place with COMBIDIC1K/-S in batches. 3. Perimeter insulation must cover the whole area and be butt jointed with COMBIDIC-2K-CLASSIC or COMBIDIC-2KPREMIUM. 4. Drainage is carried out in accordance with the specifications of DIN 4095.
Storage conditions Storage Store in a frost-free, cool and dry place. At min. 5 - 40 °C for 12 months in the original canister. Promptly use opened container.
Disposal Product residues can be disposed of in accordance with disposal code AVV 17 03 02.
Notes Protect surfaces that are not to be treated from the effects of ASOL-FE! Negative water pressure cannot be absorbed by bituminous waterproofing. It is necessary to apply waterproofing with AQUAFIN®-1K beforehand in the areas in which this can be expected. Protect masonry work tops and open window parapets against water penetration. Do not apply during rain or with air / substrate temperatures below +5 °C. Protect ASOL-FE from weathering influences such as rain, frost, strong solar radiation, etc. until totally dry!
Observe applicable safety data sheet! GISCODE: BBP10 Explanations Conformity / Declaration / Verification
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 3/4
Technical data sheet ASOL-FE
The rights of the buyer with regard to the quality of our materials are based on our terms and conditions of sale and delivery. Our technical advice team will be happy to advise you in the case of requirements that exceed the scope of the application described here. In order to be binding, a legally binding written confirmation is required. The product description does not release the user from a duty of care. Lay a test area in the event of uncertainty. This version becomes invalid in the event of a new version being issued.